This is an old revision of the document!
Table of Contents
Texscan wideband amplifier
Overview
Forward Path
Diplex filters are splitters, the Pad and Equal modules are just a flat 3dB attenuator for example, the Equal is a a frequency equalisation module (Americanism is “Slope”)
The dark brown module is a distribution unit, the dipped middle is the power amplifier module.
This lower poto shows the location of the power output isolator links (attached to the end of the cable ties)
Reverse path and Status Monitoring
The Texscan module fitted inside the trunk and supertrunk amplifiers, and used the band up to 5MHz to communicate to the central monitoring system. I don't believe this was ever put in to active service however as the reports were that the status monitoring was less reliable than the amplifiers and reported false positives too often to be believed. The brand name was “Vital Signs”.
It looks like the address for the unit is set via the blue jumper strip, this all preceeds TCP/IP etc, so I have no idea what the address structure or protocols would be like. I don't even know if this was one way, or if the central controller could talk to each monitor individually to interrogate it.
Power Supply
Hybrids
Like the ProCATV amps, the Texscan DLA use Hybrid RF amplifiers, these are built on a ceramic substrate and have discrete components mounted on. https://www.sciencedirect.com/topics/engineering/hybrid-amplifier
This page has been accessed:-
Today: 3
Yesterday: 3