- | ====== 3c588 - 3Com Multiconnect repeater hub ====== | ||
- | |||
- | {{networking: | ||
- | |||
- | Despite appearances, | ||
- | |||
- | {{networking: | ||
- | |||
- | The BNC module has a jumper internally to terminate the segment so you do not have to use a TEE piece. | ||
- | It looks like a screw is available to earth the segment too. The partition LED light comes | ||
- | on solid if the segment is partioned off because of a fault, either a short or an open circuit, basically any deviation from the expected 25 Ohms (a 50 ohm terminator at each end, ie. in parallel) | ||
- | Flashing indicates the fault is cleared. The reset switch position clears the fault led. | ||
- | |||
- | Available modules:- | ||
- | * 3-port 10base-T | ||
- | * BNC coax | ||
- | * AUI 15 pin D connector | ||
- | |||
- | Also I have read of a module by Codenoll (FOIRL with ST connectors) but have not heard anything else. | ||
- | |||
- | There is a single controller module with a 9 pin D socket on the front, I believe this was intended for an uplink to a second card cage which was never released. | ||
- | |||
- | {{networking: | ||
- | |||
- | |||
- | Module for Thin Ethernet | ||
- | |||
- | {{networking: | ||
- | |||
- | |||
- | Module for AUI, this could have a AUI module fitted to convert to 10Base-T, 10Base-2 or fibre, or connect directly to a network card with an AUI cable. | ||
- | |||
- | {{networking: | ||
- | |||
- | |||
- | Module with 3x RJ45 10Base-T sockets and status LEDs. | ||
- | |||
- | {{networking: | ||