Note subnet mask needs to be entered in hex! i.e. 255.255.255.0 == ff.ff.ff.00
ibm8265_01# set device ip_address eth 192.168.1.27 ff.ff.ff.00 IP address and mask set ibm8265_01# set device default_gateway 192.168.1.1 Default gateway set ibm8265_01#
Reboot is not needed, access to telnet will now work. Note, ssh is not supported.
$ telnet ibm8265-01 Trying 192.168.1.27... Connected to ibm8265-01. Escape character is '^]'. ATM ControlPoint Switch Telnet server at address 192.168.1.27. Press Enter 8265 ATM Control Point and Switch Module (C) Copyright IBM Corp. 1997, 1999. All rights reserved. Password: Welcome to system administrator service on ibm8265_01. ibm8265_01#
ibm8265_01# show module all Slot Install Connect Operation General Information ------------------------------------------------------------------------------- 1 Y Y Y 8265 ATM MSS Server Module 2 n n n - 3 Y Y Y 8265 ATM 12 ports 25 Mbps Module 4 n n n - 5 Y Y Y 8265 ATM WAN Module with E1 + E1 Ports 6 n p n - 7 n p n - 8 n n n - 9 Y Y Y 8265 ATM Control Point and Switch Module:Active 10 Y n n < Extension > 11 n p n - 12 n n n - 13 Y n n 8265 ATM 4 ports 155 Mbps Module 14 n n n - 15 Y Y Y 8265 ATM 4 ports 155 Mbps Module 16 n p n - 17 Y Y Y 8265 ATM 4 ports 155 Mbps Module 18 Y n Y Active Controller Module 19 n n n - ibm8265_01#
Module 13 is disabled, let's enable and disable it (connected and isolated in IBM speak):-
ibm8265_01# set module 13 connected Slot 13:Module set ibm8265_01# ibm8265_01# set module 13 isolated Slot 13:Module set ibm8265_01#
Isolated means it can be swapped whilst the chassis is powered on. Slots 1 - 17 are for network modules, slots 18 & 19 are for power control modules. Note that slots 9 & 10 HAVE to be used for the CPSW module in single fabric mode, if a redundant CPSW module is fitted, it has to go in slots 11 & 12.
Port 17.1 is connected to a Fore / Marconi PCA200e 155MB/s pci card on a computer running Centos 6.5, seen below, atmsigd has been started but not ilmid, in the second example, ilmid has been started.
ibm8265_01# show port 17.1 verbose 
      Type Mode     Status
-------------------------------------------------------------------------------
17.01: UNI enabled  DOWN:Establishing  
UNI Type             : Private
Signalling Version   : Auto
ILMI status          : DOWN:Establishing  
ILMI vci             : 0.16
RB Bandwidth         : unlimited
Police admin.        : on
Signalling vci       : 0.5
RB Admin weight      : 5040
NRB Admin weight     : 5040
VPI range admin.     : 0-15 (4 bits)
VCI range admin.     : 0-1023 (10 bits) 
Connector            : SC DUPLEX
Media                : multimode fiber
Port speed           : 155000 kbps
Connection shaping   : Off.
Remote device is active
Frame format    : SONET STS-3c
Scrambling mode : frame and cell
Clock mode      : internal            
ibm8265_01# 
ibm8265_01# show port 17.1 verbose 
      Type Mode     Status
-------------------------------------------------------------------------------
17.01: UNI enabled  UP
UNI Type             : Private
Signalling Version   : Auto
> Oper Sig. Version  : 3.0
ILMI status          : UP
ILMI vci             : 0.16
RB Bandwidth         : unlimited
...edited....
Remote device is active               
Frame format    : SONET STS-3c
Scrambling mode : frame and cell
Clock mode      : internal
ibm8265_01# 
Changes are activated immediately they are made, but are not saved to nv ram so will be lost on a device reload. There are several save options, but save all does the lot in one go.
ibm8265_01# save all ibm8265_01#