| Line 2: | Line 2: | ||
| - | A | + | A ferroresonant transformer (also known as a Constant Voltage Transformer or CVT) made by the manufacturer FUBA was used in older CATV (Cable Television) systems as a robust and reliable power supply component. |
| - | ferroresonant transformer (also known as a Constant Voltage Transformer or CVT) made by the manufacturer FUBA was used in older CATV (Cable Television) systems as a robust and reliable power supply component. | + | |
| Its primary function was to provide a stable, regulated AC output voltage to power active components like line amplifiers in the cable network, even when the input AC mains voltage fluctuated significantly. | Its primary function was to provide a stable, regulated AC output voltage to power active components like line amplifiers in the cable network, even when the input AC mains voltage fluctuated significantly. | ||
| Key characteristics and purpose in CATV systems: | Key characteristics and purpose in CATV systems: | ||
| - | | + | * Voltage Regulation: It inherently provides a stable output voltage (typically within ±2-4%) despite input voltage variations of up to ±15-25% by using a magnetic core that operates in saturation. This was crucial in older CATV systems where power quality over long cable runs could be inconsistent. |
| - | Power Conditioning: | + | |
| - | Reliability and Durability: Ferroresonant transformers are known for their simple, robust construction (relying mainly on magnetics and a capacitor) with no complex electronic feedback loops, making them very reliable and durable in harsh outdoor or industrial environments. | + | |
| - | Inherent Short-Circuit Protection: The design naturally limits the output current during an overload or short circuit condition, preventing damage to the transformer and downstream equipment. | + | |
| - | Isolation: Like any transformer, | + | |
| - | FUBA (Fuba Communications, | + | * Power Conditioning: |
| + | |||
| + | * Reliability and Durability: Ferroresonant transformers are known for their simple, robust construction (relying mainly on magnetics and a capacitor) with no complex electronic feedback loops, making them very reliable and durable in harsh outdoor or industrial environments. | ||
| + | |||
| + | * Inherent Short-Circuit Protection: The design naturally limits the output current during an overload or short circuit condition, preventing damage to the transformer and downstream equipment. | ||
| + | |||
| + | * Isolation: Like any transformer, | ||
| + | |||
| + | FUBA (Fuba Communications, | ||
| + | |||
| + | |||
| + | **This is an AI generated description.** | ||
telecoms/alphafubapsu.txt · Last modified: by andrew